A. The data in this subject comes from Boeing Process Specifications BAC5001-6, BAC5001-7, BAC5001-9 and BAC5001-10. Access to the Boeing Process Specifications is available.
B. The data is general. It is not about all situations or specific installations. Use this data to help you write minimum requirements.
数据具有通用性。并非针对所有情况或特定安装。使用此数据可帮助您编写最低要求。
C. Refer to SOPM 20-00-00 for a full list of all the vendor names and addresses.
有关所有供应商名称和地址的完整列表,请参阅 SOPM 20-00-00。
2. GENERAL 通用
A. Refer to the overhaul instructions for the approved lubricant for the threads. If the overhaul instructions do not give the lubricant, refer to BAC5001-6, Table 1.
B. Lubricate O-rings and gaskets by the overhaul instructions or BAC5506 (SOPM 20-50-06).
按照大修说明或 BAC5506 (SOPM 20-50-06)润滑 O 形圈和密封垫。
C. Install and tighten the fittings, couplings or clamps by standard industry practices, the overhaul instructions, and the instructions in BAC5001-6, BAC5001-7, BAC5001-9 and BAC5001-10, as applicable.
D. Use the torque values as specified by the overhaul instructions. If the overhaul instructions do not give the torque or tell you to tighten to standard torque, use the torque values shown in Figure 1 thru Figure 4, or BAC5001-6 thru BAC5001-10, as applicable. To help you find the torque for hydraulic fittings such as unions, reducers, valves and plugs, use these guidelines:
(1) Find the thread size of the fitting. This can be measured on the actual part, or identify the fitting part number and refer to the part specification or standard, which will give the thread size and the related tube size (which can be part of the fitting part number).
(2) Find the material of the fitting, and also of the mating part (the part with the threaded hole). If the materials of the fitting and the mating part are different, note the softer material, such as aluminum compared to steel or titanium. For the purposes of this analysis, consider steel and titanium to have the same hardness.
(3) Find the torque in Figure 1, Figure 2, Figure 3 or Figure 4, or BAC5001-6 thru BAC5001-10, as applicable, for the noted material and thread size or tube size.